Aluminium Sulphate for water treatment. Its wide range of usage is in water treatment, because it can act as an coagulant, flocculant, precipitant and emulsion breaker. As coagulant and flocculant, aluminum sulfate successfully removes turbidity, suspended solids and colloidal color,reduces biochemical oxygen demand (BOD) and extremely clarifies potable, process and wastewaters.
Also used as foam fire extinguisher
Aluminium sulfate reacts with sodium bicarbonate to which foam stabilizer has been added, producing carbon dioxide for fire extinguishing foam.
The carbon dioxide is trapped by the foam stabilizer and creates a thick foam which will float on top of hydrocarbon fuels and seal off access to atmospheric oxygen, smothering the fire. Chemical foam was unsuitable for use on polar solvents such as alcohol, as the fuel would mix with and break down the foam blanket. The carbon dioxide generated also served to propel the foam out of the container, be it a portable fire extinguisher or fixed installation using hoselines. Chemical foam is considered obsolete in the United States and has been replaced by synthetic mechanical foams, such as AFFF which have a longer shelf life, are more effective, and more versatile, although some countries such as Japan and India continue to use it.
In the construction industry, it is used as waterproofing agent and accelerator in concrete.
- For the production of Aluminum salts, Soaps and Aluminum Hydroxide Gel. - As a Catalyst in Ethane Production.
- Textile industry.
- Paper production.
- For the production of Glycerin
- As a Foaming Agent in Fiber Foams.
- As a Clearing Agent for Fats and Foams. - In sugar industry.
|
Item |
Index |
|
|
Aluminum Sulfate |
15.8% |
17% |
|
A12O3 % ≥ |
15.8 |
17 |
|
Iron Fe content % ≤ |
0.50 |
0.005 |
|
Water insoluble matter % ≤ |
0.15 |
0.15 |
|
PH value 1% aqueous solution ≥ |
3.0 |
3.0 |
|
Heavy metals as Pb % ≤ |
0.002 |
0.002 |
|
AS % ≤ |
0.0005 |
0.0005 |
|
Granularity ≥ |
----- |
15 |
|
Item |
Index |
|
|
Aluminum Sulfate |
15.8% |
17% |
|
A12O3 % ≥ |
15.8 |
17 |
|
Iron Fe content % ≤ |
0.50 |
0.005 |
|
Water insoluble matter % ≤ |
0.15 |
0.15 |
|
PH value 1% aqueous solution ≥ |
3.0 |
3.0 |
|
Heavy metals as Pb % ≤ |
0.002 |
0.002 |
|
AS % ≤ |
0.0005 |
0.0005 |
|
Granularity ≥ |
----- |
15 |
|
Item |
Index |
|
|
Aluminum Sulfate |
15.8% |
17% |
|
A12O3 % ≥ |
15.8 |
17 |
|
Iron Fe content % ≤ |
0.50 |
0.005 |
|
Water insoluble matter % ≤ |
0.15 |
0.15 |
|
PH value 1% aqueous solution ≥ |
3.0 |
3.0 |
|
Heavy metals as Pb % ≤ |
0.002 |
0.002 |
|
AS % ≤ |
0.0005 |
0.0005 |
|
Granularity ≥ |
----- |
15 |
properties :::---
1. Properties: Including anhydrous and hydrous(18 crystal water) type. Usually, the crystal separated out from aqueous solution at the normal temperature is A12(SO4) 3.18H2O; When weathering, the average molecular structure is A12(SO4) 3.14H2O, may appear white powdery, with bright flake or crystalline flakelet, odorless, to change the taste from sweetness to slight astringency.
2. Uses: Solidifying agent ( to purify grease and water ) and stabilizer in pasteurization of albumin ( including: liquid or refrigerated whole egg, egg white or egg yolk ), the maximum allowable use level ( FAO/WHO.1984 ) is 0.036%.
3. Standard: HG2225-2001
4. State: Flake or powder
5. Packing: 25/50 kg/bag, 25MT/20'FCL
ALUMINIUM SULFATE Al2(SO4)3

| Product Name | ALUMINIUM SULFATE |
| Part Number | RXSOL-19-1904-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail@rxmarine.com | |
| Website | www.rxmraine.com |

Substances
| Formula | Al2O12S3 |
| Molecular weight | 342,15 g/mol |
| CAS-No. | 10043-01-3 |
| EC-No. | 233-135-0 |
| Component | Classification | Concentration |
| Aluminium sulfate | ||
|
CAS-No. 10043-01-3
EC-No. 233-135-0
|
Met. Corr. 1; Eye Dam. 1;
H290, H318
|
= 100 % |

Classification of the substance or mixture
| Classification according to Regulation (EC) No 1272/2008 |
Corrosive to Metals (Category 1), H290
Serious eye damage (Category 1), H318
For the full text of the H-Statements mentioned in this Section, see Section 16.
|
Label elements
| Signal Word | Danger |
| Hazard statement(s) |
H290 May be corrosive to metals.
H318 Causes serious eye damage.
|
| Precautionary statement(s) |
P234 Keep only in original packaging.
P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue rinsing.
P390 Absorb spillage to prevent material damage.
|
| Supplemental Hazard Statements | None |
| Signal Word | Danger |
| Hazard statement(s) | H318 Causes serious eye damage. |
| Precautionary statement(s) |
P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue rinsing.
|
| Supplemental Hazard Statements | None |
| Other hazards | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |

| General Advice | Show this material safety data sheet to the doctor in attendance. |
| If inhaled | After inhalation: fresh air. |
| In case of skin contact | In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. |
| In case of eye contact | After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses. |
| If swallowed | After swallowing: immediately make victim drink water (two glasses at most). Consult a physician. |
| Most important symptoms and effects, both acute and delayed | The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 |
| Indication of any immediate medical attention and special treatment needed | No data available |

| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Unsuitable extinguishing media | For this substance/mixture no limitations of extinguishing agents are given. |
| Special hazards arising from the substance or mixture |
Sulfur oxides
Aluminum oxide
Not combustible.
Ambient fire may liberate hazardous vapours.
|
| Advice for firefighters | In the event of fire, wear self-contained breathing apparatus. |
| Further information | Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system. |

| Personal precautions, protective equipment and emergency procedures |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
For personal protection see section 8.
|
| Environmental precautions | Do not let product enter drains. |
| Methods and material for containment and cleaning up | Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up with liquid-absorbent material (e.g. Chemizorb® ). Dispose of properly. Clean up affected area. |
| Reference to other sections | For disposal see section 13. |

| Precautions for safe handling | For precautions see section 2.2. |
| Storage conditions |
No metal containers.
Tightly closed. Dry.
hygroscopic Store under inert gas.
|
| Storage class | Storage class (TRGS 510): 8B: Non-combustible, corrosive hazardous materials |
| Specific end use(s) | Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |

| Eye/face protection | Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles |
| Body Protection |
Protective clothing
|
| Respiratory protection |
Required when dusts are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type P2
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
|
| Control of environmental exposure | Do not let product enter drains. |

| Physical state | Powder |
| Color | White |
| Odor | Odorless |
| Melting point/freezing point | Melting point/range: 770 °C - dec. |
| Initial boiling point and boiling range | 112 - 116 °C |
| Flammability (solid, gas) | The product is not flammable. - Flammability (solids) |
|
Upper/lower flammability or explosive limits
|
No data available |
| Flash point | No data available |
| Autoignition temperature | No data available |
| Decomposition temperature | No data available |
| pH | No data available |
| Viscosity |
Viscosity, kinematic: No data available
Viscosity, dynamic: No data available
|
| Water solubility |
ca.0,00001 g/l at 21,5 °C - insoluble
|
| Partition coefficient: n-octanol/water | Not applicable for inorganic substances |
| Vapor pressure | No data available |
| Density | 2,71 g/mL at 25 °C - lit. |
| Relative density | No data available |
| Relative vapor density | No data available |
| Particle characteristics | No data available |
| Explosive properties | No data available |
| Oxidizing properties | None |
| Other safety information | No data available |

| Reactivity |
No data available
|
| Chemical stability | The product is chemically stable under standard ambient conditions (room temperature) |
| Possibility of hazardous reactions | No data available |
| Conditions to avoid |
Air Exposure to moisture.
No information available
|
| Incompatible materials | No data available |
| Hazardous decomposition products | In the event of fire: see section 5 |

| Acute toxicity |
LD50 Oral - Rat - male and female - > 2.000 mg/kg
(OECD Test Guideline 401)
Inhalation: No data available
LD50 Dermal - Rabbit - male and female - > 5.000 mg/kg
(OECD Test Guideline 402)
|
| Skin corrosion/irritation |
Skin - Rabbit
Result: No skin irritation - 4 h
(OECD Test Guideline 404)
|
| Serious eye damage/eye irritation |
Eyes - Rabbit
Result: Irreversible effects on the eye
(OECD Test Guideline 405)
|
| Respiratory or skin sensitization |
Local lymph node assay (LLNA) - Mouse
Result: negative
(OECD Test Guideline 429)
|
| Germ cell mutagenicity |
Test Type: Ames test
Test system: Escherichia coli/Salmonella typhimurium
Metabolic activation: with and without metabolic activation
Method: OECD Test Guideline 471
Result: negative
Test Type: In vitro mammalian cell gene mutation test
Test system: mouse lymphoma cells
Metabolic activation: with and without metabolic activation
Method: OECD Test Guideline 476
Result: negative
Test Type: Micronucleus test
Test system: Human lymphocytes
Metabolic activation: with and without metabolic activation
Method: OECD Test Guideline 487
Result: negative
Test Type: Micronucleus test
Species: Rat
Application Route: Oral
Method: OECD Test Guideline 474
Result: negative
Remarks: (in analogy to similar products)
The value is given in analogy to the following substances: aluminium hydroxide
Species: Rat
Application Route: Oral
Remarks: Cytogenetic analysis
|
| Carcinogenicity | No data available |
| Reproductive toxicity |
No data available
|
| Specific target organ toxicity - single exposure | No data available |
| Specific target organ toxicity - repeated exposure | No data available |
| Aspiration hazard | No data available |
|
Additional Information
Endocrine disrupting properties
|
|

| Toxicity | |
| Toxicity to fish |
Semi-static test LC50 - Danio rerio (zebra fish) - > 87,5 mg/l - 96 h
(OECD Test Guideline 203)
|
| Toxicity to daphnia and other aquatic invertebrates |
Static test EC50 - Daphnia magna (Water flea) - > 200 mg/l - 48 h
(OECD Test Guideline 202)
|
| Toxicity to algae |
Static test ErC50 - Pseudokirchneriella subcapitata (microalgae) -
0,24 mg/l - 72 h
(OECD Test Guideline 201)
|
| Toxicity to bacteria |
Static test EC50 - activated sludge - > 200 mg/l - 3 h
(OECD Test Guideline 209)
|
| Persistence and degradability | The methods for determining biodegradability are not applicable to inorganic substances. |
| Bioaccumulative potential | No data available |
| Mobility in soil | No data available |
| Results of PBT and vPvB assessment | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |
|
Endocrine disrupting properties
Product
|
|
| Assessment | The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. |
| Other adverse effects | No data available |

| Waste Treatment Methods | No data available |

| UN number | ADR/RID: 3260 IMDG: 3260 IATA: 3260 |
| UN proper shipping name |
ADR/RID: CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate)
IMDG: CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate)
IATA: Corrosive solid, acidic, inorganic, n.o.s. (aluminium sulfate)
|
| Transport hazard class(es) | ADR/RID: 8 IMDG: 8 IATA: 8 |
| Packaging group | ADR/RID: lll IMDG: lll IATA: lll |
| Environmental hazards | ADR/RID: No IMDG Marine pollutant: No IATA: No |
| Special precautions for user | |
| Tunnel restriction code | (E) |
| Further information | No data available |

| Safety, health and environmental regulations/legislation specific for the substance or mixture | This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006. |
| Other regulations | Take note of Dir 94/33/EC on the protection of young people at work. |
| Chemical Safety Assessment | For this product a chemical safety assessment was not carried out |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchant ability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own nvestigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, how so ever arising, even if Rx Marine International has been advised of the possibility of such damages. |