Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical:
Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical – Complete Solution for Boiler Protection
Boilers are critical equipment in marine and industrial operations, and maintaining proper water quality is essential for efficient performance and long service life. Poor boiler water treatment can lead to scale formation, corrosion, sludge buildup, and reduced heat transfer efficiency. AUTOTREAT Boiler Water Treatment Chemical is specially formulated to provide complete protection for boiler systems.
Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with Oxygen Scavenger Plus. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and no adherent for easy removal by blow down. The product should always be used in conjunction with an oxygen scavenger, preferably RXSOL Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.
Boiler Water Treatment Chemical Autotreat : Autotreat is a multifunctional, liquid boiler water treatment, formulated with alkaline compounds, scale inhibitor, dispersant, and volatile amines for the protection of the feed, boiler and condensate systems.
What is Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical?
Boiler Water Treatment AUTOTREAT is a multi-functional boiler water treatment chemical designed to control alkalinity, corrosion, scale formation, and sludge deposition in boiler systems. Its advanced formulation helps maintain clean boiler internals, ensuring safe and efficient operation.
It is widely used in:
-
Marine boilers
-
Industrial steam boilers
-
Heating systems
-
Auxiliary boilers
-
Closed water circulation systems
Why Boiler Water Treatment is Important?
Untreated boiler water can cause:
-
Scale formation that reduces heat transfer
-
Corrosion leading to metal damage and leaks
-
Sludge accumulation causing blockages
-
Fuel wastage due to poor efficiency
-
Boiler downtime and expensive repairs
Using a quality boiler treatment chemical like AUTOTREAT helps avoid these problems.
The product should preferably be dosed continuously with a Rxsol Boiler Water Treatment Dosing Unit. Alternatively the product can be fed into the feed line by means of a by-pass pot feeder.
Dosage and control
Minimum dosage is 1.2 liters of Autotreat/ton of boiler capacity to reach a P-Alkalinity level of 100 ppm. For an untreated system it is recommended to initially bring the treatment up to a suitable level of 200 ppm p-Alkalinity. The dosage chart given below is for convenience to determine the amount of product required to elevate P-Alkalinity. Note that the table is based on reaching 200 ppm. P-Alkalinity.
Sampling and testing
A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Spectrapak Test Kit instructions and log the results. It is important that regular testing is carried out to ensure that treatment levels are correct.
Key Benefits of Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical
1. Prevents Scale Formation
Boiler Water Treatment AUTOTREAT controls hardness salts and prevents scale buildup inside boiler tubes.
2. Controls Corrosion
Protects boiler metal surfaces against oxygen and acidic corrosion.
3. Maintains Alkalinity
Helps maintain the proper pH and alkalinity level for efficient boiler operation.
4. Reduces Sludge Build-Up
Conditions suspended solids for easy removal during blowdown.
5. Improves Boiler Efficiency
Keeps heat transfer surfaces clean for better fuel economy.
6. Extends Boiler Life
Regular use helps prolong the lifespan of boiler systems.
Autotreat is a specialized boiler water conditioner engineered for maximum system protection. It combines proven phosphate treatment with advanced polymer technology. The formulation ensures scale and sludge remain soft and non-adherent. Easier removal through blow down improves operational efficiency. When used with RXSOL Oxygen Scavenger Plus, it provides complete boiler protection.
- Advanced phosphate–polymer blend for superior conditioning
- Keeps deposits soft, loose, and easy to remove
- Enhances efficiency and reduces maintenance costs
- Works synergistically with RXSOL Oxygen Scavenger Plus for full system protection
TOTAL BOILER PROTECTION
Why Choose Boiler Water Treatment AUTOTREAT?
Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical provides reliable all-in-one protection against scale, corrosion, and sludge, making it an ideal choice for marine and industrial boiler systems. It improves efficiency, reduces maintenance costs, and ensures safe boiler operation.
Keywords:
AUTOTREAT Boiler Water Treatment Chemical, Boiler Water Treatment Chemical, Marine Boiler Chemical, Industrial Boiler Chemical, Boiler Scale Inhibitor, Boiler Corrosion Inhibitor, Boiler Sludge Conditioner
Applications of Boiler Water Treatment AUTOTREAT
-
Marine boiler water treatment
-
Industrial boiler maintenance
-
Steam generation systems
-
Auxiliary boiler protection
-
Closed-loop heating systems
How to Use Boiler Water Treatment AUTOTREAT Boiler Chemical
-
Test boiler water parameters.
-
Dose Boiler Water Treatment AUTOTREAT directly into the boiler feed system.
-
Maintain recommended alkalinity and pH levels.
-
Perform regular blowdown to remove sludge.
-
Monitor water quality for best results.
Dosage depends on boiler capacity and water conditions.
- Liquid boiler water treatment chemical for simplified dosing and handling.
- Suitable for all boilers, up to 30 Bar pressure.
- Prevents scaling and corrosion, increasing system life and reliability.
- Contains volatile amines to neutralize acids occurring in condensate system.
- Dispersant action suspends sludge and sediment particles for efficient removal by blow down.
- Suitable for dosing with Rxsol Boiler Water Treatment Dosing Unit.
- Keeps boiler tube surfaces clean, promoting the best heat transfer conditions, saving energy.
- Simple testing to determine treatment level.
Boiler Water Treatment Chemicals Full range ::: https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boiler-Maintenance-Solutions
Marine Chemicals Full Range ::: https://marinechemical.in/marine-chemicals-full-range
Auto Treat boiler chemicals available in 25, 30, 50 Ltr pack.
![]()
| Product Name | : | RXSOL-50-5020-025 |
| Product Type | : |
BOILER WATER TREATMENT AUTO TREAT |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
| Phone | : | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | : | +91 22 2781 1318 :::AOH :0091 9821214367 |
| : | mail@rxmarine.com , sales@tankcleaner.net/ | |
| Website | : | www.rxmarine.com/ , www.tankcleaner.net/ |

| Chemica Name | Concentration | CAS Number | EC Number | R Phrases* | Symbols |
| Potassium hydroxide | 1-5 | 1310-58-3 | 215-181 | 22-35 | C |
| Tripotassium phosphate | 1-5 | 7778-58-3 | 231-907-1 | - | - |
| Proprietory Blend Polymer and Chelating Agent | 80-90 | --- | --- | --- | --- |
*See Section 16

![]()
Corrosive
| Odour | Odourless |
| Appearance | Liquid, colour less to yellow, soluble in water |
| Contact with eyes | Corrosive to eyes, Can cause damage to the eyes |
| Contact with skin | Causes burns(R34) |
| Inhalation | No information available but must be considered harmful |
| Ingestion | Harmful if swallowed(R22) |

| Contact with skin | Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash withsoap and water. Seek medical advice if necessary |
| Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15minutes |
| Ingestion |
Do not induce vomiting Never give anything by mouth to anunconscious person Give water or milk to drink Obtain immediate medical attention |
| Inhalation |
Inhalation is unlikely to occur Seek medical attention if ill effects occur |
| General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)(S45) |

- Non combustible
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
|
Personal Precautions |
Wear protective clothing as persection 8 |
| Environmental Precautions | No special precautions are required for this product |
| Clean Up Actions |
Absorb spillageininert material and shovelup |
| Special Precautions | Wear protective clothing as persection 8 |

|
Handling |
Wear protective clothing as persection 8 |
| Storage |
Keep only in the original container in a cool, well ventilated place(S3/9/49) |

|
Exposure Limits |
TLV(TWA)2mg/m3(Potassium hydroxide) |
|
Exposure controls |
No special precautions are required for this product |
|
Occupational exposure controls |
Wear suitable protective clothing,including eye/face protection and gloves(plastic or rubbera recommended) |
![]()
Gloves Goggles Suit No_Smoking

| Odour | Odourless |
| Appearance | Liquid, colour less to yellow, soluble in water |
| pH | 13at 100%concentration |
| pH9.5 | 11at 0.2 %concentration |
| Boiling point > | 100degreeCat 760mm/Hg |
| Vapourpressure | not known |
| Vapourdensity | not applicable |
| Freezing point | 0degreeCat 760mm/Hg |
| Soluble in water | Completely |
| Specific gravity | (water=1)1.135 |

- This article is considered stable under normal conditions
- Avoid over heating, Keep away from frost
- In compatible with acid
- See Section 5

|
Toxicological information |
No experimental data available |
| Inhalation | In halation is unlikely to occur |
| Contact with skin | Prolonged skin or eye contact may cause chemical burns |
| Contact with eyes | Prolonged skin or eye contact may cause chemical burns |
| Ingestion | The ingestion of significant quantities may cause burning sensation |
| Carcinogenicity | No evidence of carcinogenic effects |

| Ecotoxicity | May cause acute effects in the aquatic environment |
| Mobility | Completely soluble in water |
| Persistence and Biodegradability | Degrades by hydrolysis |
| Bioaccumulation Potential | Bioaccumulation of the components in this product is insignificant. |
| Other Adverse Effects |
No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment. Presents little or no hazard to the aquatic environment |

|
Classification |
EUWasteclass: 06.02 This material and/or its container must be disposed of as hazardous |
| Disposal considerations |
Do not discharge into drains or the environment,dispose to an authorised waste collection point |

ProperShippingName: POTASSIUMHYDROXIDE, SOLUTION
UN
ProperShippingName:
UNNo.:
Potassiumhydroxide, solution
1814
HazardClass:
Road/Rail(ADR/RID)
ProperShippingName:
ADRUNNo.:
ADRHazardClass:
8PackingGroup:
Potassiumhydroxide, solution
1814
8
III
ProperShippingName:
IMDG UNNo.:
Revision: 31/12/2008
Potassiumhydroxide, solution
1814
IMDG HazardClass.:
IMDG EmS:
IMDG Labels:
Air(ICAO/IATA)
ProperShippingName:
ICAO UnNo.:
ICAO HazardClass.:
ICAO subrisk:
ICAO Flashpoint:
8IMDG PackGroup.:
F-A, S-BIMDG subrisk:
8IMDG Flashpoint:
Potassiumhydroxide, solution
1814
8ICAO PackingGroup.:
N/AICAO Labels:
N/A
III
N/A
N/A
III
8, CAO
DOT/ CFR(USDepartment ofTransportation
DOTProperShippingName:Potassiumhydroxide, solution
HazardousMaterial:
potassiumhydroxide
HazardClass:
Product RQ (lbs):
DOTLabels:
- For bidden on passenger air craft

| RiskPhrases | : | Causesburns (R34) |
| SafetyPhrases | : |
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice(S26) In case of accident or if you feel unwell, seek medical advice immediately(show the label where possible)(S45) |
![]()
Text ofRandSphrasecodesusedinthissafetydatasheet:- R22: Harmfulifswallowed; R35: Causessevereburns.
Theinformationprovidedabout theproduct onthis SafetyDataSheet hasbeencompiledfromknowledge
of theindividualconstituents Thedatagivenhereisbasedoncurrent knowledgeandexperience.
ThisSafetyDataSheet describestheproduct intermsofsafetyrequirementsanddoesnot signify any
warrantywithregardtotheproduct'sproperties .Thedatagivenhereonlyapplieswhenproduct used
forproperapplication(s). Theproduct isnot sold assuitable forotherapplications-usage in such
may cause risks not mentioned inthissheet. Donot useforother application(s)without seekingadvicefrommanufacturer
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.