| Product Name | Cationic Polyacrylamide Flocculant |
| Part Number |
RXSOL-40-4160-051 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Surat, Mumbai, Chennai, Vizag, Kolkata, UAE, OMAN and KENYA
| Phone | +91 22 27815540 / 41 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123@rxmarine.com | |
| Website | www.rxmarine.com |

| Name of Substance | Cas Number | EINECS No | Wt.% |
| Polyacrylamide | 9003-05-8 | 618-350-3 | 100% |

| Signal Word | None |
| Hazard Statements |
No data available |
| Precautionary statements |
No data available |
| Precautionary statements |
No data available |

| Eye Contact |
Rinse with pure water for at least 15 minutes. Consult a doctor. |
| Skin Contact |
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor. |
| Inhalation |
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical. |
| Ingestion |
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately. |

| Suitable extinguishing media | Use dry chemical, carbon dioxide or alcohol-resistant foam. |
| Extinguishing media which must not be used for safety reasons: | No data available |
| Special exposure hazards arising from the substance itself, combustion products, resulting gases: | No data available |
| Special protective equipment for fire-fighters: |
Wear self-contained breathing apparatus for firefighting if necessary. |
| Additional information: | No data available |

| Personal precautions, protective equipment and emergency procedures |
Avoid dust formation. Avoid breathing mist, gas or vapours. Avoid contacting with skin and eye. Use personal protective equipment. Wear chemical impermeable gloves. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. |
| Enviromental Precaution |
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided. |
|
Methods and materials for containment and cleaning up |
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.. |

| Precautions for safe handling |
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam. |
| Conditions for safe storage, including any incompatibilities |
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
|

| Engineering Control |
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area. |
| Personal Protection |
Eye/face protection : Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Skin protection : Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Respiratory protection : If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
|

| Form | White to faintly Yellow Granules |
| Colour | No data available |
| Odour | No data available |
| Boiling point and boiling range | 122°C |
| Flash Point | 113°C |
| Melting point | 241°C(lit.) |
| pH | No data available |
| Evaporation rate | No data available |
| Flammability (solid, gas) | No data available |
| Upper explosion limit | No data available |
| Lower explosion limit | No data available |
| Explosive properties | No data available |
| Vapor pressure | No data available |
| Relative vapor density | No data available |
| Relative density | 1.189g/mLat 25°C |
| Water solubility | No data available |
| Solubility in other solvents | No data available |
| Partition coefficient: octanol | No data available |
| Autoignition temperature | No data available |
| Thermal decomposition | No data available |
| Viscosity, kinematic | No data available |
| Explosive properties | No data available |
| Oxidizing properties | No data available |
| Molecular weight | No data available |
| VOC | No data available |

| Recativity | None |
| Stability | No data available |
| Possibility of hazardous reactions | No data available |
| Incompatible materials | No data available |
| Hazardous Decomposition |
No data available |
| Condition to Avoid | None Known |

| Route of Exposure | Inhalation, Eye contact, Skin contact |
| Acute toxicity |
Oral: no data available
Inhalation: no data available
Dermal: no data available
|
| Skin corrosion/irritation | No data available |
| Serious eye damage/irritation | No data available |
| Respiratory or skin sensitization | No data available |
|
Germ cell mutagenicity
|
No data available |
| Carcinogenicity | No data available |

| Environmental Effects | No data available |
| Toxicity to fish | No data available |
| Toxicity to daphnia and others | No data available |
| Toxicity to algae | No data available |
| Biodegradability | No data available |
| Persistence and degradability | No data available |
| Bioaccumulative potential | No data available |
| Mobility in soil | No data available |

| Disposal methods |
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems. |
| Contaminated packaging |
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials. |

| ADR/RID | Not dangerous goods. |
| IMDG | Not dangerous goods. |
| IATA | Not dangerous goods. |

Safety, health and environmental regulations specific for the product in question :
| European Inventory of Existing Commercial Chemical Substances (EINECS) |
Not Listed.
|
| EC Inventory | Not Listed. |
| United States Toxic Substances Control Act (TSCA) Inventory |
Listed.
|
| China Catalog of Hazardous chemicals 2015 | Not Listed. |
| New Zealand Inventory of Chemicals (NZIoC) |
Listed.
|
| Philippines Inventory of Chemicals and Chemical Substances (PICCS) |
Listed.
|
| Vietnam National Chemical Inventory |
Listed.
|
| Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) |
Listed.
|

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. |