Inhibitor for Citric ACID
Citric Acid corrosion Inhibitor is an organic, liquid, cationic corrosion inhibitor especially designed to inhibit the attack of Citric Acid during industrial cleaning operations. It also inhibits acid attack on copper and brass.
The addition of Acid corrosion Inhibitor Citric Acid inhibitors to Citric acid solution provides maximum protection for equipment during:
A. The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equipment.
B. The removal of scale and deposits from equipment in refineries, utility companies,paper mills, chemical plants and other industries.
Citric acid is a weak organic acid. It is a natural preservative/conservative and is also used to add an acidic, or sour, taste to foods and soft drinks. In biochemistry, the conjugate base of citric acid, citrate, is important as an intermediate in the citric acid cycle, and therefore occurs in the metabolism of virtually all living things.
For each For each 1000ltrs of pickling bath Citric Acid Inhibitor must be added at the rate of 1 to 5ltrs (1.1 - 5.7kgs)* Citric acid solution, not less than the following amount of Citric Acid corrosion Inhibitor should be used:
The exceptional strength and heat stability of Citric Acid corrosion Inhibitor give the user a considerable safety factor in relation to temperature, acid strength, and time. Citric Acid corrosion Inhibitor may be added to either the diluted or concentrated Citric acid Solution. In either case, Citric Acid corrosion Inhibitor should be thoroughly mixed with the acid by stirring or agitation.
The hydrochloric acid solution inhibited with Citric Acid corrosion Inhibitor is best circulated through the equipment to be cleaned. When circulation cannot be accomplished, the equipment should be filled with the inhibited acid and allowed to react for sufficient time to remove the objectionable deposits. To estimate the proper acid concentration and cleaning time, samples of the deposits to be removed can be tested in the laboratory prior to cleaning. If heating of the equipment to be cleaned or acid solution is desired to speed the cleaning action, it should be done prior to the start of the cleaning operation
ACID inhibitor for Citric Acid.
Storage and Disposal
Citric Acid Corrosion Inhibitor and will not freeze at temperature as low as -20° Fahrenheit. Below 0° Fahrenheit, Citric Acid Corrosion Inhibitor become very viscous and may be difficult to pump. It is recommended that Citric Acid Corrosion Inhibitor be stored in a dry area where the temperature will not go lower than 0° Fahrenheit.
Applicable regulations concerning disposal and discharge of chemicals should be consulted and followed-
Disposal information for Citric Acid Corrosion Inhibitor is given on the Material Safety Data Sheet for each product.The industrial cleaning bath is acidic and contains Citric acid and organic Citric Acid Corrosion Inhibitor components. Waste treatment , neutralization is required. The industrial cleaning bath and sludge can contain ingredients other than those in the chemical as supplied and analysis of the solution and/or sludge is required before waste treatment and disposal.
Safety and Handling :
Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.
Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Citric Acid Corrosion Inhibitor protect your downhole equipment and metal tubulars.

| Product Name | RXSOL-45-1503-005 |
| Product Type | Citric Acid Corrosion Inhibitor |
Supplier Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Surat, Kolkata, Chennai, Vizag, FUjairah, Muscat
| Phone | +91 22 65113333 / 5555 / 9999 / 27815540 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| care@rxmarine.com |

|
Chemical Name |
CAS Number |
% |
|
Complex substitude Keto-Amine-Hydrochloride |
Proprietary |
10 - 30 |
|
2 - Propanol |
67-63-0 |
10 - 30 |
|
Alkylphenol ethoxylate |
Proprietary |
5 - 10 |
| Propargyl alcohol | 107-19-7 | 5 - 10 |
| Butenone | 78-94-4 | 1 - 5 |
| Acetone | 67-64-1 | 1 - 5 |
| Acetophenone | 98-86-2 | 0.1 - 1 |
| Diethyl Thio UREA | 27598-95-4 | 5.0% |
| Propylene Glycol | 57-55-6 | 1.0% |
| HEXAMINE | 100-97-0 | 1.0% |
| Disodium COCOampho Dipropionate | 68604-71-7 | 20% |
|
DTPMPA
|
.......... | 10% |
| HEDP | 10% |

|
Odour |
solvent
|
|
Appearance |
Brown
|
|
Contact with eyes |
Contact can cause moderate to severe irritation and possible injury to the eyes. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.
|
|
Contact with skin |
corrosive to the skin contact with the skin or mucous membtranes may cause severe irritation and burn this product contin component that cause allergic damage including |
|
Inhalation |
This product is irritating to the respiratory system. Repeated inhalation may be harmful; lung irritation and serious central nervous system disorders may result. Excessive inhalation of this can cause headache, dizziness, nausea and incoordination. |
|
Ingestion |
Ingestion can cause gastrointestinal irritation, nausea, vomiting and diarrhea. May be harmful or fatal if swallowed. |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water Seek medical advice if necessary |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes .Obtain immediate medical attention Ingestion, Never give anything by mouth to an unconscious person Give plenty of water to drink |
|
Ingestion |
Get immidiate medical attention. Do not induce vomiting. |
|
Inhalation |
If mist or vapor of this product is inhaled, remove person immediately to fresh air. Seek medical attention if symptoms devolop or persist. |

|
FlashPoint: |
680 F(200 c) Tagliague closed cup |
| Autoignition tempreture: |
Not determined |
| Flammabble/Explosive limits - lower : |
Not determined |
| Flammabble/Explosive limits - upper : |
Not determined |
| Extinguishing media : |
Foam, Dry chemical or carbon dioxide. Water may be an ineffective extinguishing medium . In case of fire , keep containers cool with water spray. |
| Speacial firefighting procedures : |
Wear full protective clothing . Wear self - contained breathing apparatus. |
| Unusual fire or explosion hazards : |
Fire and Explosion hazards are DANGEROUS when this material is exposed to heat or flame . Vapors are heavier than air and may travel along floor to an ignition source. |
| Hazardous combustion products : |
Irritation and toxic gases or fumes may be released during a fire. |
| Sensitive to Mechanical impact: |
Not available |
| Sensitive to static discharge : | Not available |

|
Personal Precautions |
Wear protective clothing as per section 8 |
|
Environmental Precautions: |
Ventilate area. Pervent further leakage or spillage if safe to do so. Eliminate all source of ignition or flammables that may come into contact with a spill of this material. Wear appropriate protective equipment and clothing during clean- up. |
|
Clean Up methods: |
Absorb Spill with inert material. Shovel material into appropriate container for disposal. Dispose of according to Federal, State and local government regulations. |

|
Handling |
Avoid contact with eyes. Avoid contact with skin and clothing. Wash throughly after handling . Avoid breathing vapors or mists of this product . Do not take internally. For industrial use only . keep away from heat, spark and flame. |
|
Storage |
For safe storage , store between 0OF (-17.8OC) and 120O F (48.9OC) keep container tightly closed and in a cool, well- ventilated place away from incompatible materials. Remove all Source of iginition. |

|
Engineering controls: |
Use general vantilation and loal exhaust, where possible, in confined or enclosed spaces. |
|
Respiratory protection : |
If venitilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided. |
|
Eye/face protection: |
Wear chemical goggles; face shield (if splashing is possible). |
| Skin protection : | Chemical resistant, impermeable gloves . Gloves should be tested to determine suitability for prolonged contact . use of imprevious apron and boots are recommanded. |

| Physical state | Liquid |
| color | Brown |
|
Odour |
solvent |
|
Odour threshold |
Not available |
| pH | 2 |
|
Vapor pressure |
Not determined |
|
Boiling point/range |
>82.2 °C (> 108OC) |
| Melting point/ range |
-20OF (-28.9OC) |
| Specific gravity | 1.02 - 1.05 at 60OF (15.56OC) |
| Vapor density | Not determined |
| Flash point | 68OF ( 20OC) Tangliabue closed cup |
| Flammable / Explosive limits - lower | Not determined |
| Flammable / Explosive limits - upper | Not determined |
| Autoignition tempreture | Not determined |
| Evaporation rate | Not determined |
| Solubility in water | Appreciable |
|
Partition coefficient (n-octanol/water) |
Not determined |
| VOC content | 27.2% EPA Method 24 |

Stability - stable at normal conditions
Hazardous reactions - Will not occur.
Hazardous decomposition products - Upon decompsition, this product may yield oxides of nitrogen and ammonia ,carbon dioxide
carbonmonoxide and other low molecular weight hydrocarbons.
Incompable materials - This product may reat wiyh strong alkalies. Keep sepreate from strong oxidizing and strong
reducing agents . Do not mix with chlorides.
Conditions to Avoids - Keep away from heat, ignition source and incompatible materials.

|
Toxicological information |
No experimental data available Inhalation. |
|
Contact with skin |
In cases of severe exposure, redness and irritation may develop. |
|
Contact with eyes |
Causes irritation. |
|
Ingestion |
May cause gastro-intestinal disturbances |
|
Carcinogenicity |
No evidence of carcinogenic effects. |

|
Ecological information: |
Harmful to aquatic organisms . |

|
Recommanded methods of disposal: |
Dispose of according to Federal, state and local gov |

canada transporation of dangerous goods ground
proper shipping name liquid corrsive N.O.S.
hazard class of division 3(8)
identification number UN2924
packing group II
international air transportion
proper shipping name liquid crossive n.o.s.
hazard class or division 3(8)
identification number UN2924
packing group II
water transportion
proper shipping name liquid crossive n.o.s.
hazard class or division 3(8)
identification number UN2924
packing group II

Canada regulartory information
CEPA DSL NDSL All compenents are listed on or are exempt from listing on the canadian domastic substance list.
United states regulatory information
TSCA 8 (B) Inventory status All compenents are listed on or are exempt from listing on the Toxic substance control act inventory

Text of R and S phrase codes used in this safety data sheet:- R34: Causes burns; R36: Irritating to eyes; R37: Irritating to respiratory system; R41: Risk of serious damage to eyes. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.