Resine Mixed Bed

Mixed Bed resins, a mixture of cation and anions are used as polishers to obtain low conductivity water. Typically, low conductivity water is required for bolier feed for high pressure boilers, electronics, electrical discharge cutting machines and p
Category

Mixed Bed resins, a mixture of cation and anions are used as polishers to obtain low conductivity water. Typically, low conductivity water is required for bolier feed for high pressure boilers, electronics, electrical discharge cutting machines and pharmaceutical applications.

Mixed Bed can also be used as a primary deionisation unit when the inlet salt is low. Mixed Beds also find applications in process industry where demineralization of pH sensitive products is to be carried out.

Application

The Poular application is as below -

  • Ultra pure water production
  • Demineralisation
  • Deionisation 
  • Condensate polishing (boiler feed water)
  • Micro-electronics cleaning
  • Pharmaceuticals
  • Metal Removal
Dose

Each application requires a different water quality. In general cation resin for water softening and demineralization may last 5 to 10 years. Anion resins used in demineralization last anywhere from 3 to 5 years and are dependent on operational conditions. Like every other resin, the life of mixed bed resin is dependent on the application in which it is being used. Resin life is difficult to predict; in critical applications it's best to start analyzing and benchmarking the resin at least once per year.

Technical specifications
 

Form

: Solid Granular Form

Color

: Golden Light 

Odor

: Odorless

Odour threshold

: Not determined.

pH-value

: Not applicable.

Melting point/Melting range

: undetermined

Boiling point/Boiling range

: undetermined

Flash point

: Not applicable

Flammability (solid, gaseous)

: Not determined.

Decomposition temperature

: Not determined

Auto igniting

: Product is not selfigniting.

Danger of explosion

: Product does not present an explosion hazard

Explosion limits Lower

: Not determined

Explosion limits Upper

: Not determined.

Vapor pressure

: Not applicable.

 

Form

: Solid

Color

: Blue

Odor

: Odorless

Odour threshold

: Not determined.

pH-value

: Not applicable.

Melting point/Melting range

: undetermined

Boiling point/Boiling range

: undetermined

Flash point

: Not applicable

Flammability (solid, gaseous)

: Not determined.

Decomposition temperature

: Not determined

Auto igniting

: Product is not selfigniting.

Danger of explosion

: Product does not present an explosion hazard

Explosion limits Lower

: Not determined

Explosion limits Upper

: Not determined.

Vapor pressure

: Not applicable.

 
Note

Mixed Bed Resins can be supplied in highly regenerated, premixed conditions for use in dye applications or they are also available as highly regenerated cations and anions for use in regeneratable mixed bed units. Premixed Resin is available in different proportions and combinations of cations and anions to suit the end of users needs.

NOTE: Mixed Beds are generally used in applications where water of very low conductivity is desired.

Remarks / Precaution

The presence of certain metal ions in water causes a variety of problems. These ions interfere with the action of soaps. They also lead to build up of limescale, which can foul plumbing, and galvanic corrosion.

Conventional water-softening appliances intended for household use depend on an ion-exchange resin in which “hardness ions” – mainly Ca2+ and Mg2+- are exchanged for sodium ions. Ion exchange devices reduce the hardness by replacing magnesium and calcium (Mg2+ and Ca2+) with sodium or potassium ions (Na+ and K+).”

Ion-exchange softeners are used extensively in small water systems and individual homes apart from Industry. Ion-exchange resin, exchanges one ion from the water being treated for another ion that is in the resin (sodium is one component of softening salt, with chlorine being the other). Ion Exchange resin exchanges sodium for calcium and magnesium. The following chemical reactions show the exchange process, where R represents Resin, the exchange material.

Removal of carbonate hardness:

Ca(HCO3)2 + Na2R ——> CaR + 2NaHCO3

Mg(HCO3)2 + Na2R ——> MgR + 2NaHCO3

Removal of non-carbonate hardness:

CaSO4 + Na2R —– > CaR + Na2SO4

CaCl2 + Na2R ——> CaR + CaCl2

MgSO4 + Na2R ——> MgR + Na2SO4

MgCl2 + Na2R ——> MgR + 2NaC1

Ion exchange resins are organic polymers containing anionic functional groups to which the divalent cations (Ca++) bind more strongly than monovalent cations (Na+).

Ion-exchange does not alter the water’s pH or alkalinity. However, the stability of the water is altered due to the removal of calcium and magnesium and slight increase in dissolved solids. For each ppm of calcium removed and replaced by sodium, total dissolved solids increase by 0.15 ppm. For each ppm of magnesium removed and replaced by sodium, total dissolved solids increase by 0.88 ppm.

When all the available Na+ ions have been replaced with calcium or magnesium ions, the resin must be re-charged by eluting the Ca2+ and Mg2+ ions using a solution of sodium chloride. The waste waters eluted from the ion exchange column containing the unwanted calcium and magnesium salts are typically discharged to the sewage system in case of household units.

Packing sizes
<br />
MSDS

Product Name RXSOL-32-3101-025
Product Type Mixed Bed Resine

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail@rxmarine.com

Substances - Not classified as a hazardous substance or mixture.

Classification of the substance or mixture :

Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008
This substance is not classified as dangerous according to Directive 67/548/EEC.

Odour

Amine odor

Appearance

Amber or brown

Contact with eyes

slight irritation

Contact with skin

slight irritation

Contact with skin

flush eyes with a large ammount of water for at least 15 min consult a physician if irritation persists

Contact with eyes

wash skin thoroghly with soap and water

Flash point

NA

Auto-ignition temp. 500.c/932.F Estimate
lower explosive limt NA
uppe rexplosive limt NA
If  inhaled  : If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin    contact : Wash off with soap and plenty of water.
 
In case of eye contact : Flush eyes with water as a precaution.
If swallowed : Never give anything by mouth to an unconscious person. Rinse mouth with water.

Suitable extinguishing media : Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special hazards arising from the substance or mixture : Nature of decomposition products not known.

Advice for firefighters : Wear self contained breathing apparatus for fire fighting if necessary.

Further information : No data available

Personal Precautions

Wear gloves of cotton canvvas or leather

additional personal protective eq.

safety glasses(ANSI Z87.1 or approved equivalent)

Personal precautions, protective equipment and emergency procedures : Avoid dust formation. Avoid breathing vapors, mist or gas.

Environmental precautions : Do not let product enter drains.

Methods and materials for containment and cleaning up : Sweep up and shovel. Keep in suitable, closed containers for disposal.

Reference to other sections : For disposal see section 13.


Storage

avoid temperature extremes during storage ambient temperature perferred avoid repeated freez-thaw cycles beads may fracture if frozen thaw at room temperature

Precautions for safe handling : Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire protection.

Conditions for safe storage, including any incompatibilities : Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Specific end uses : no data available.

 

Personal protective equipment :

Eye/face protection: Use equipment for eye protection tested and approved under appropriate government standards
such as NIOSH (US) or EN 166(EU).

Skin protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications.
 

Body Protection :
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
 

Respiratory protection :
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

 
respiratory proection

respiratory proection program meeting OSHA 1910,134 and ANSI Z88.2 requirment must be followed whenever workplace condition warrant a respirator use none req. under normal operating condition

Eye protecton

use safety glasses

hand protection

avoid skin contact when useing this substance use cotton , canvas, leather gloves

 
 Appearance Form : Small beads
Colour : Amber / brown
Odour :

No data available

Odour Threshold :

No data available

 pH :

No data available

Melting point/freezing point : No data available
Initial boiling point and boiling range :

No data available

Flash point :

No data available

Evaporation rate :

No data available

Flammability (solid, gas) :

No data available

Upper/lower flammability or explosive limits :

No data available

Vapour pressure :

No data available

Vapour density :

No data available

Relative density :

No data available

Water solubility :

No data available

Partition coefficient: noctanol/water :

No data available

Viscosity :

No data available

Explosive properties :

No data available

- incompatibility:-avoid contact with strong oxidizing particulary concentrated nitric acid
- Hazardous polymerization:-product will not undergo polymerization

:-Not applicable Data

:-Not applicable Data

Unused resin may be incinerated or landfilled in facilities meeting local state and federal reguation for contaminated resin the user must determine the hazard and use an appropriate disposal method.

Not  Classified as a hazardous for transport by, road, air and sea.

This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.

Safety, health and environmental regulations/legislation specific for the substance or mixture : No data available
Chemical Safety Assessment : No data available

Text of R and S phrase codes used in this safety data sheet:- R34: Causes burns; R36: Irritating to eyes; R37: Irritating to respiratory system; R41: Risk of serious damage to eyes. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable..

 Appearance Form : Small beads
Colour : Amber / brown
Odour :

No data available

Odour Threshold :

No data available

 pH :

No data available

Melting point/freezing point : No data available
Initial boiling point and boiling range :

No data available

Flash point :

No data available

Evaporation rate :

No data available

Flammability (solid, gas) :

No data available

Upper/lower flammability or explosive limits :

No data available

Vapour pressure :

No data available

Vapour density :

No data available

Relative density :

No data available

Water solubility :

No data available

Partition coefficient: noctanol/water :

No data available

Viscosity :

No data available

Explosive properties :

No data available

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@kolkatachemical.com